Home / Azure

AzureTroubleshootingIntermediate

Azure VM clock drift: Kerberos skew, token and TLS errors fixed with chrony, /dev/ptp_hyperv and w32time

Logins fail with clock skew, token or SAS calls are rejected as expired, or TLS says a certificate is not yet valid. Find the drifting Azure VMs and fix their time source.

Deepak Bhardwaj7 min read

Applies toAzure VMs running Linux with chrony (RHEL, Ubuntu, SLES, Azure Linux) and Windows Server 2016-2025 with w32time

Symptoms

A VM's clock is minutes off and something that checks timestamps starts failing:

Symptom Where you see it Why time matters
KRB_AP_ERR_SKEW, "The time difference between the client and server", domain logons fail Windows event logs, SSSD/realmd on Linux Kerberos rejects tickets outside the allowed skew (5 minutes by default)
AADSTS700024: Client assertion is not within its valid time range App or pipeline using a certificate credential The signed assertion's nbf/exp claims are judged against Entra ID's clock
Storage returns 403 AuthenticationFailed with "Request date header too old" SDK or REST calls to Blob, Queue, Table Shared key requests carry a date that must be close to the service's time
"Certificate is not yet valid" or "expired" on a fresh certificate curl, browsers, .NET, Java Validity windows are checked against the local clock
TOTP codes rejected, cron jobs at the wrong time, log lines out of order Anywhere The clock is simply wrong

How Azure VMs keep time

Azure hosts expose their clock to guests through Hyper-V integration services, so a VM can stay in sync without reaching any network time server.

  • Linux: the hv_utils driver exposes a PTP hardware clock. Recent endorsed images create a udev symlink /dev/ptp_hyperv; older ones only have /dev/ptp0 (or another number). chrony reads it as a refclock PHC.
  • Windows: the VM IC Time Synchronization Provider (VMICTimeProvider) feeds w32time from the host. Standalone VMs also use NTP to time.windows.com. Domain members follow the domain hierarchy (NT5DS).

Most drift comes from one of three things. The host source has been disabled or misconfigured. The VM depends on an NTP server it can't reach. Or two time daemons are fighting over the clock.

Check 1: how far off is the VM?

You can measure from outside without logging in by using Run Command:

RG=rg-app; VM=vm-app01

# Linux
az vm run-command invoke -g $RG -n $VM --command-id RunShellScript \
  --scripts "date -u; chronyc tracking; chronyc sources -v" \
  --query "value[0].message" -o tsv

# Windows
az vm run-command invoke -g $RG -n $VM --command-id RunPowerShellScript \
  --scripts "(Get-Date).ToUniversalTime(); w32tm /query /source; w32tm /query /status" \
  --query "value[0].message" -o tsv

Compare date -u or the PowerShell UTC time with a known-good clock. In chronyc tracking, look at System time (the current offset) and Leap status (Normal is good, Not synchronised is not).

Tip

To sweep a fleet, loop the same Run Command over az vm list -g $RG --query "[].name" -o tsv. Run Command executes one script per VM at a time, so run them in sequence or in small batches.

Check 2 (Linux): is chrony using the Hyper-V clock?

ls -l /dev/ptp*                          # expect ptp0 and, on newer images, ptp_hyperv -> ptp0
cat /sys/class/ptp/ptp0/clock_name       # expect "hyperv"
chronyc sources -v                       # the PHC line should be marked with '*' (selected)
grep -E "^(refclock|server|pool|makestep)" /etc/chrony.conf /etc/chrony/chrony.conf 2>/dev/null
systemctl is-active chronyd chrony systemd-timesyncd ntpd 2>/dev/null
timedatectl status

What healthy looks like in chronyc sources:

MS Name/IP address         Stratum Poll Reach LastRx Last sample
===============================================================================
#* PHC0                          0   3   377     6   +12us[ +15us] +/- 1500ns
Finding Cause Fix
No refclock PHC line in the config Custom or hardened image with the Azure config removed Add the refclock line below
refclock PHC /dev/ptp_hyperv but the device doesn't exist Older image without the udev rule Point it at the right /dev/ptpN, after checking that clock_name says hyperv
PHC source shows ? or Reach 0 Wrong device, or hv_utils not loaded lsmod | grep hv_utils, then fix the device path
Only pool/server lines, all with ? Outbound UDP 123 blocked by an NSG, firewall or forced tunnel Use the PHC refclock. It needs no network
chronyd and systemd-timesyncd (or ntpd) both active Two daemons stepping the clock Disable all but chrony

The configuration Microsoft documents for Azure looks like this. File paths vary by distribution (/etc/chrony.conf on RHEL and SLES, /etc/chrony/chrony.conf on Ubuntu):

refclock PHC /dev/ptp_hyperv poll 3 dpoll -2 offset 0 stratum 2
makestep 1.0 -1

Apply it and correct the clock right away:

sudo systemctl disable --now systemd-timesyncd 2>/dev/null
sudo systemctl restart chronyd 2>/dev/null || sudo systemctl restart chrony
sudo chronyc makestep
chronyc tracking

Warning

chronyc makestep jumps the clock instead of slewing it. A large backwards step can confuse databases, message brokers and anything that orders events by local time. On a database or cluster node, step during a quiet window, or let chrony slew small offsets.

Check 3 (Windows): what is w32time actually using?

w32tm /query /source
w32tm /query /status
w32tm /query /configuration
w32tm /query /peers
w32tm /stripchart /computer:time.windows.com /samples:5 /dataonly
w32tm /query /source returns Meaning Action
VM IC Time Synchronization Provider Syncing from the Azure host Normal for standalone VMs
time.windows.com,0x8 (or your NTP server) Syncing over NTP Check that UDP 123 outbound is allowed
A domain controller name Domain hierarchy Check the DC, and ultimately the PDC emulator
Local CMOS Clock or Free-running System Clock Not syncing at all Fix the configuration below

Check that the host provider is enabled:

Get-ItemProperty "HKLM:\SYSTEM\CurrentControlSet\Services\W32Time\TimeProviders\VMICTimeProvider" -Name Enabled

On a standalone (workgroup) VM that has drifted, set a reachable NTP peer, keep the host provider on, then resync:

Set-ItemProperty "HKLM:\SYSTEM\CurrentControlSet\Services\W32Time\TimeProviders\VMICTimeProvider" -Name Enabled -Value 1
w32tm /config /manualpeerlist:"time.windows.com,0x8" /syncfromflags:manual /update
Restart-Service w32time
w32tm /resync /rediscover
w32tm /query /status

On a domain member, don't hard-code peers. Run w32tm /config /syncfromflags:domhier /update, restart w32time and resync. If several members are wrong by the same amount, the problem is the DC.

Caution

The PDC emulator is the time source for the whole forest. Changing its configuration or stepping its clock moves every domain member with it. Check the current setup with w32tm /query /configuration and w32tm /monitor first. Make one deliberate change, and follow Microsoft's current guidance for domain controllers hosted in Azure. Don't leave a mix of host sync and external NTP that nobody chose on purpose.

Check 4: can the VM reach its NTP server?

This only matters if the VM relies on NTP rather than the host clock:

# Effective NSG rules on the NIC, looking for outbound UDP 123
az network nic list-effective-nsg -g $RG -n vm-app01-nic \
  --query "value[].effectiveSecurityRules[?direction=='Outbound' && (destinationPortRange=='123-123' || destinationPortRange=='0-65535')].{name:name,access:access,prio:priority}" -o table

# From inside a Linux VM
chronyc -N sources

With a forced tunnel to on-premises, or an Azure Firewall without a rule for UDP 123, NTP queries just time out. Either allow the flow or rely on the host clock, which needs no network access.

Prevent it next time

  • Keep the Azure time configuration in your golden images. Hardening scripts often strip the refclock PHC line or turn off the VMIC provider.
  • Run exactly one time daemon on Linux. Mask systemd-timesyncd if chrony is the standard.
  • Add a scheduled check, through Run Command, Azure Policy guest configuration or your monitoring agent, that alerts when the chronyc tracking offset or the w32tm /query /status source looks wrong.
  • Document the AD time hierarchy, especially which source the PDC emulator uses, and review it after DC migrations.
  • Treat KRB_AP_ERR_SKEW and AADSTS700024 as time problems first. Check the clock before you rotate credentials.