When you actually need this
Use multi-node serving only when the model's weights plus a useful KV cache don't fit on one node, even after quantization. Before you build it, check these alternatives:
- FP8 or INT4 weights on one 8-GPU node, which roughly halves or quarters the weight memory.
- A smaller or distilled model that passes your evaluation set.
- A managed endpoint for the one model that needs it.
A multi-node server is a single failure domain spread over more hardware. If one GPU, NIC or pod goes down, the whole server goes down. Plan your replicas and capacity around that.
Choose the parallel layout
| Layout | Traffic pattern | Network need | Good for |
|---|---|---|---|
| TP = GPUs per node, PP = number of nodes | All-reduce inside the node; activations pass between nodes once per stage | Moderate between nodes | Default choice |
| TP across all GPUs on all nodes | All-reduce across nodes on every layer | InfiniBand/RoCE with GPUDirect RDMA | Lowest latency, only on very fast fabrics |
| PP only | Point-to-point between stages | Low | Nodes without NVLink; throughput over latency |
| Data parallel (separate servers) | None between replicas | None | When the model fits on one node: always prefer this |
The vLLM docs recommend tensor parallel size = GPUs per node and pipeline parallel size = number of nodes. For two 8-GPU nodes, that is --tensor-parallel-size 8 --pipeline-parallel-size 2.
Pipeline parallelism adds a stage-to-stage hop per forward pass, so single-request latency is a little worse. It keeps all-reduce traffic on NVLink, which matters far more than that hop.
Prerequisites on every node
All nodes must run the same environment, or Ray workers fail in confusing ways:
- The same container image, which means the same vLLM, PyTorch, CUDA and NCCL versions.
- The model weights at the same path on every node: a shared read-only volume, or an identical local copy.
- Matching GPU models and driver versions.
- Open ports between nodes for Ray (head port, default 6379) and NCCL (ephemeral TCP, plus RDMA if used).
Check the in-node fabric first:
nvidia-smi topo -m # expect NV# links between GPUs, not PHB/SYS
ibv_devinfo | grep -E 'hca_id|state|link_layer' # if using InfiniBand/RoCE
Build the Ray cluster
Set the network interfaces explicitly. Otherwise NCCL may pick a management NIC or a Docker bridge, and you get timeouts or very slow throughput.
# On every node (adjust interface names to your hosts)
export NCCL_SOCKET_IFNAME=ib0 # or the high-speed Ethernet interface
export GLOO_SOCKET_IFNAME=ib0
export NCCL_IB_HCA=mlx5 # only with InfiniBand/RoCE
export VLLM_HOST_IP=$(ip -4 addr show ib0 | awk '/inet /{print $2}' | cut -d/ -f1)
Head node:
ray start --head --port=6379 --node-ip-address="$VLLM_HOST_IP"
Each worker node:
ray start --address="<head-ip>:6379" --node-ip-address="$VLLM_HOST_IP"
Verify before you start vLLM:
ray status # expect 16 GPUs for 2 x 8
ray list nodes # every node ALIVE, with the expected IPs
vLLM also ships a helper script for this (multi-node-serving.sh with leader and worker roles) in its examples. Use it if you would rather not write your own entrypoint.
Start vLLM on the head node only
vllm serve /models/llama-3.1-405b-instruct-fp8 \
--served-model-name llama-405b \
--tensor-parallel-size 8 \
--pipeline-parallel-size 2 \
--distributed-executor-backend ray \
--max-model-len 32768 \
--gpu-memory-utilization 0.90 \
--host 0.0.0.0 --port 8000
Only the head node serves HTTP. The worker nodes host Ray actors that hold their share of the layers.
Warning
Turn on
NCCL_DEBUG=INFOfor the first start and read which transport NCCL chose. Lines that mentionNET/Socketwhen you expectedNET/IBmean inter-node traffic is going over TCP. The server still works, but at a fraction of the throughput. Turn the variable off afterwards, because it is noisy.
NCCL_DEBUG=INFO vllm serve ... 2>&1 | grep -E 'NET/|Using network|NCCL INFO Channel' | head
Verify it works
curl -s localhost:8000/v1/models | jq '.data[].id'
curl -s localhost:8000/v1/chat/completions -H "Content-Type: application/json" \
-d '{"model":"llama-405b","messages":[{"role":"user","content":"Reply with OK"}],"max_tokens":5}'
Then benchmark with your real prompt and output lengths, and compare the result with a single-node baseline of a quantized variant:
vllm bench serve --model llama-405b --base-url http://localhost:8000 \
--dataset-name random --random-input-len 2000 --random-output-len 300 \
--num-prompts 300 --max-concurrency 32
On older releases, the benchmark is benchmarks/benchmark_serving.py in the vLLM repo, not vllm bench serve.
Watch these metrics on the head node's /metrics:
| Metric | Meaning on multi-node |
|---|---|
vllm:time_to_first_token_seconds | Rises sharply if inter-node links are slow (prefill crosses stages) |
vllm:num_requests_waiting | Queueing; with PP, too few concurrent requests leaves stages idle |
vllm:kv_cache_usage_perc (older: vllm:gpu_cache_usage_perc) | KV pressure; names vary by version |
Pipeline stages only stay busy when several requests are in flight. A multi-node PP server looks slow in single-request tests and much better at realistic concurrency, so test at realistic concurrency.
Running it on Kubernetes
Use a group-aware controller so leader and workers are scheduled, restarted and scaled as one unit. LeaderWorkerSet (LWS) is the pattern the vLLM docs show. The essentials:
size: 2(one leader and one worker per group); each pod requestsnvidia.com/gpu: 8.- The leader runs
ray start --headand thenvllm serve; the worker runsray start --address=$(LWS_LEADER_ADDRESS):6379 --block. - Use
restartPolicy: RecreateGroupOnPodRestart, so a failed worker recreates the whole group instead of leaving a half-alive server. - Add a readiness probe on the leader's
/healthand a long startup probe, because loading hundreds of GB of weights takes many minutes. - Give it a
/dev/shmvolume (emptyDirwithmedium: Memory) and, for RDMA, the device plugin resources your fabric needs.
Caution
Don't put a multi-node group on spot or preemptible nodes without spare capacity. Losing any one node kills the whole server and the cold start is long. Keep at least N+1 groups for production, or a smaller fallback model behind the same gateway route.
Failure modes you inherit
| Symptom | Cause | Fix |
|---|---|---|
| Hangs at start-up, then NCCL timeout | Wrong interface, firewall, or one node on a different image | Set NCCL_SOCKET_IFNAME/GLOO_SOCKET_IFNAME, check ports, compare image digests |
ray status shows fewer GPUs | Worker joined with the wrong IP or no GPU visibility | Check --node-ip-address and the GPU device plugin |
| Low throughput, high TTFT | NCCL fell back to sockets | Check NCCL_DEBUG=INFO for NET/IB |
| Whole server dies when one pod restarts | Expected: one failure domain | Group restart policy, N+1 groups |
| Placement group creation hangs | Not enough free GPUs in the Ray cluster | Remove stale Ray actors, or restart the Ray cluster |
Prevent it next time
- Record a known-good baseline (tokens/s and TTFT at fixed concurrency) and rerun it after every image, driver or fabric change.
- Pin image digests, not tags, so all nodes are guaranteed identical.
- Alert on group restarts and on NCCL transport fallbacks found in logs.
- Review every quarter whether a quantized single-node deployment now passes your evaluation. It is cheaper and simpler to run.
Get the weekly HubDatAI email